Standard | Option | |
Wetted material | 1.4404/316L and 1.4401/316 dual certified stainless steel (NACE MR 0175 / MR 0103 compliant) |
Stainless steel electropolished for food and pharmaceutical industry, Hastelloy®, titanium, Monel®, 6Mo, Inconel®, PTFE liner |
Process connections | EN/ASME/JIS flange DN15-DN150 | Screw connection, clamp, welding ends, threaded connection, aspectic connections |
Display housing | Aluminium die casting, coated | Stainless steel |
Ex-design | Intrinsically safe: Ex-i (IS) Non-sparking:Ex-nA (NI) |
Explosion proof: Ex-d (XP) Dust ignition proof: Ex-t (DIP) |
Electronics features | Measurement and indication without power supply | Modular: • Limit switches (NAMUR, transistor, reed) • 2-wire current output 4...20 mA HART® 7 • FOUNDATION™ ITK6 fieldbus/PROFIBUS® PA • Totaliser with digital display and pulse output |
Mounting position/ direction of flow |
Vertical/from bottom to top | Horizontal/from left to right or right to left Vertical/from top to bottom |
Error limit according to VDI/VDE3513-2 (qG=50%) | 1.6% | Precision calibration on request |
Measuring span | 10:1 | 100:1 |
Accessories | • Magnetic filter, if the medium contains particles which can be magnetically influenced • Float damping, for pulsating flows or low operating pressures (particularly when measuring gases) • Pointer damping for easy reading of measured value • Heating jacket for measuring cone |
• Magnetic filter, if the medium contains particles which can be magnetically influenced • Float damping, for pulsating flows or low operating pressures (particularly when measuring gases) • Pointer damping for easy reading of measured value • Heating jacket for measuring cone |